100% candidates have passed the 920-434 exam by the help of CertBus pass guaranteed 920-434 preparation materials. The CertBus Nortel PDF and VCEs are the latest and cover every knowledge points of 920-434 Communication Server 1000 Rls. 5.x Applications Engineering certifications. You can try the questions and answerss for an undeniable success in 920-434 exam.
We CertBus has our own expert team. They selected and published the latest 920-434 preparation materials from Nortel Official Exam-Center: http://www.certgod.com/920-434.html
QUESTION NO: 149
An administrator tries to dynamically increase the processor capacity entitlement of LPAR1 from 1.0 to 2.0.
The current entitlement is 1.0 and the maximum is set to 3.0.
The operation fails. When the administrator adds up the number of processors in use by the currently
running LPARs, there are 4 processors available. The administrator also notes that LPAR2 is inactive.
What is the cause of this failure?
A. LPAR1 has “Allow when partition active” in the Processor Sharing section CHECKED in its profile
B. LPAR2 has “Allow when partition inactive” in the Processor Sharing section NOT CHECKED in its
profile
C. LPAR2 has “Allow when partition inactive” in the Processor Sharing section CHECKED in its profile
D. LPAR1 has “Allow when partition active” in the Processor Sharing section NOT CHECKED in its profile
Correct Answer: B
QUESTION NO: 15
Which of the following are three areas that favor IBMs position in Web2.0 computing?
A. Acquisition cost, speed and density
B. High performance processors, cooling and reliability
C. Power, cooling and density
D. Acquisition cost, density and reliability
Answer: C
QUESTION NO: 164
What is the default number of NPIV adapters which can be assigned by the Power Hypervisor?
A. 500
B. 1024
C. 32000
D. 65536
Correct Answer: C
QUESTION NO: 110
An administrator receives the following error while performing a backup of a VIO Server.
What can the administrator do to backup the VIO Server successfully?
A. Edit the /etc/security/limits file and change the fsize field to -1.
B. Increase the size of the /home/padmin/backup filesystem.
C. Change the ownership of the /home/padmin/backup directory to padmin.
D. Run the backupios command again using the -mksysb flag
Correct Answer: D
QUESTION NO: 161
A VIO server requires redundancy on its Shared Ethernet Adapter (SEA). The SEA is backed by physical
adapter ent0 and virtual adapter ent2, ent0 and ent1 are the interfaces on a dual-port Ethernet adapter.
What network redundancy technique should be suggested?
A. ent1 should be used to set up a Network Interface Backup through ‘smitty etherchannel1. The new
Etherchannel adapter should be used as the backing device for the SEA
B. ent1 should be used to set up Link Aggregation through ‘smitty linkagg1. The new Link Aggregation
adapter should be used as the backing device for the SEA
C. Create a new SEA using another virtual Ethernet adapter on the VIO Server and assign ent1 as the
backing device. Assign this SEA to the clients and setup Link Aggregation on the clients.
D. Setup the SEA failover control channel to use the ent1 physical adapter as the backup control channel.