All4Certs Cisco Archive,Exam Archive,Oracle Archive [Newest Version] Easily Pass 300-175 Exam with CertBus Updated Real Cisco 300-175 Exam Materials

[Newest Version] Easily Pass 300-175 Exam with CertBus Updated Real Cisco 300-175 Exam Materials

CertBus 2019 Latest Cisco 300-175 CCNP Data Center Exam VCE and PDF Dumps for Free Download!

300-175 CCNP Data Center Exam PDF and VCE Dumps : 416QAs Instant Download: https://www.certgod.com/300-175.html [100% 300-175 Exam Pass Guaranteed or Money Refund!!]
☆ Free view online pdf on CertBus free test 300-175 PDF: https://www.certgod.com/online-pdf/300-175.pdf

Following 300-175 416QAs are all new published by Cisco Official Exam Center

100% candidates have passed the CCNP Data Center Hotest 300-175 vce exam by the help of CertBus pass guaranteed CCNP Data Center Hotest 300-175 vce preparation materials. The CertBus Cisco PDF and VCEs are the latest and cover every knowledge points of CCNP Data Center Sep 27,2019 Hotest 300-175 vce dumps DCUCI Implementing Cisco Data Center Unified Computing (DCUCI) certifications. You can try the Q and As for an undeniable success in Hotest 300-175 pdf exam.

pass 300-175 exam | 300-175 written test | 300-175 exam study guide | 300-175 exam tips. CertBus 300-175 certification questions. CertBus – professional 300-175 certification exam dumps provider. we do all things to help with your exams. CertBus – help candidates on all 300-175 certification exams preparation. pass 300-175 certification exams, get 300-175 certifications easily.

We CertBus has our own expert team. They selected and published the latest 300-175 preparation materials from Cisco Official Exam-Center: https://www.certgod.com/300-175.html

Question 1:

In order to manually boot from the FlexFlash SD card, which boot option must be in the boot policy used in the service profile?

A. FlexFlash state

B. remote virtual drive

C. remote boot

D. SD card

Correct Answer: D

https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-c-series-rack-servers/whitepaper-c11-734876.html#_Toc459341669 To boot from an SD card, the SD card must be present in the boot policy used in the service profile…


Question 2:

Which two items represent the features of Call Home on the Cisco Unified Computing System? (Choose two.)

A. syslog

B. send fault details to Cisco TAC

C. SNMP trap receiver

D. send email alerts to administrators

E. central repository of normalized fault data

Correct Answer: BD


Question 3:

You plan to configure a Fibre Channel port channel on a Cisco UCS system.

What is the maximum number of port channels and ports per port channel on a Cisco UCS 6200 Series device?

A. four Fibre Channel port channels and 24 Fibre Channel ports per port channel

B. eight Fibre Channel port channels and 24 Fibre Channel ports per port channel

C. eight Fibre Channel port channels and 16 Fibre Channel ports per port channel

D. four Fibre Channel port channels and 16 Fibre Channel ports per port channel

Correct Answer: D

https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/configuration_limits/2-0/b_UCS_Configuration_Limits_2_0.html https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/Reference-Docs/Configuration-Limits/3-1/b_UCS_Configuration_Limits_3_1.html


Question 4:

You need to configure storage switch-based Fibre Channel zoning in a Cisco UCS system. The zoning must be configured in VSAN 100 What Should you do?

A. Disable zoning on VSAN 100 in Cisco UCS Manager. Configure zoning on the upstream SAN switch on VSAN 100.

B. Disable zoning on VSAN 100 in Cisco UCS Manager. Set Cisco UCS Manager to interoperability mode Create VSAN 100 in Cisco UCS Manager. Configure zoning on the upstream third-party SAN switch.

C. Register the SAN switch manually in Cisco UCS Manager. Enable switch-based zoning on VSAN 100 in Cisco UCS Manager.

D. Discover the SAN switch in Cisco UCS Manager. Enable inherited zoning on VSAN 100 in Cisco UCS Manager.

Correct Answer: A


Question 5:

You plan to use AAA security services for a Cisco UCS Fabric Interconnect. Which two authentication providers can you use? (Choose two.)

A. Kerberos

B. RADIUS

C. NTLM

D. Diameter

E. LDAP

Correct Answer: BE


Latest 300-175 Dumps300-175 Exam Questions300-175 Braindumps

Question 6:

Which two tasks can you perform from Cisco UCS Manager? (Choose two.)

A. Configure SAN PIN groups.

B. Restart an Oracle database.

C. Configure or manage external storage on the SAN.

D. Configure QoS classes and definitions.

E. Deploy an operating system.

Correct Answer: AD

Restart an Oracle database. NOT CORRECT Deploy an operating system. NOT CORRECT Configure or manage external storage on the SAN. NOT CORRECT https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-2/b_UCSM_GUI_Configuration_Guide_2_2/b_UCSM_GUI_Configuration_Guide_2_2_chapter_010101.html https://www.cisco.com/c/en/us/support/docs/ servers-unified-computing/ucs-2104xp-fabric-extender/110509-ucs-qos-00.html#qos_policy https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/1-0-2/b_GUI_Config_Guide/GUI_Config_Guide_chapter19.html


Question 7:

Which two statements about MAC addresses in the Cisco UCS are true? (Choose two.)

A. The first 2 octets represent the manufacturer OUI.

B. The first 3 octets represent the manufacturer OUI.

C. The last 3 octets are assigned by the organization itself.

D. The last 4 octets are assigned by the organization itself.

Correct Answer: BC

https://supportforums.cisco.com/t5/unified-computing-system/oui-for-wwn-and-macs/td-p/1441710 https://supportforums.cisco.com/t5/unified-computing-system/when-to-use-wwnn-and-wwpn-pools/td- p/1614344 http:// www.vmwareadmins.com/using-a-address-naming-convention-with-cisco-ucs/ https://en.wikipedia.org/wiki/MAC_address


Question 8:

Which two parameters are used by Cisco UCS for automatic Fibre Channel uplink pinning?

A. server WWN

B. MDS WWNN

C. VSAN membership

D. hash algorithm

E. vHBA MAC address

Correct Answer: AC

https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/3-0/ b_UCSM_GUI_User_Guide_3_0/b_UCSM_GUI_User_Guide_3_0_chapter_011000.html https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/

gui/config/guide/2-0/ b_UCSM_GUI_Configuration_Guide_2_0/

b_UCSM_GUI_Configuration_Guide_2_0_chapter_010110.html#task_2F3F6BFFC4384A2F8809492F9DE 8FD23


Question 9:

You are implementing a UCS B-Series environment for a customer with both bare-metal and virtualized servers.

The bare-metal servers require two vNICs and two vHBAs. Administrators of virtualized servers will be utilizing VN-Link technology.

Which adapter should be recommended?

A. Cisco UCS M81KR

B. Cisco UCS M72KR-Q

C. Cisco UCS M71KR-E

D. Cisco UCS P81E

E. Cisco UCS M51KR-B

Correct Answer: A

M81KR (supports many adapters and VN-LINK)

https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-b-series-blade-servers/ data_sheet_c78-525049.html M72KR-Q (supports only one adapter, does not support VN-LINK) https://www.cisco.com/c/en/us/

products/collateral/servers-unified-computing/ucs-b-series-blade-servers/ data_sheet_c78-623738.html M71KR-E (supports only one adapter, does not support VN-LINK) https://www.cisco.com/c/en/us/products/collateral/servers-unifiedcomputing/ucs-b-series-blade-servers/ data_sheet_c78-703582.html P81E (supports many adapters, does not support VN-LINK) https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-c-series-rack-servers/

data_sheet_c78-558230.html M51KR-B (this is not a converged network adapter CNA, and does not support vHBAs) https://www.cisco.com/c/dam/en/us/products/collateral/servers-unified-computing/ucs-b-series-blade- servers/

spec_sheet_c17-644236.pdf


Question 10:

When deploying Nexus 5000 switches in NPV mode, what technology will help with resilience and increase throughput?

A. F-port-channel trunk

B. FCoE

C. Other answer (unknown)

D. Other answer (unknown)

Correct Answer: A

https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/san_switching/421_n1_1/ b_Cisco_n5k_nxos_sanswitching_config_guide_rel421_n1_1/ Cisco_n5k_nxos_sanswitching_config_guide_rel421_n1_1_chapter7.html#con_133799


CertBus exam braindumps are pass guaranteed. We guarantee your pass for the 300-175 exam successfully with our Cisco materials. CertBus DCUCI Implementing Cisco Data Center Unified Computing (DCUCI) exam PDF and VCE are the latest and most accurate. We have the best Cisco in our team to make sure CertBus DCUCI Implementing Cisco Data Center Unified Computing (DCUCI) exam questions and answers are the most valid. CertBus exam DCUCI Implementing Cisco Data Center Unified Computing (DCUCI) exam dumps will help you to be the Cisco specialist, clear your 300-175 exam and get the final success.

300-175 Cisco exam dumps (100% Pass Guaranteed) from CertBus: https://www.certgod.com/300-175.html [100% Exam Pass Guaranteed]

Why select/choose CertBus?

Millions of interested professionals can touch the destination of success in exams by certgod.com. products which would be available, affordable, updated and of really best quality to overcome the difficulties of any course outlines. Questions and Answers material is updated in highly outclass manner on regular basis and material is released periodically and is available in testing centers with whom we are maintaining our relationship to get latest material.

BrandCertbusTestkingPass4sureActualtestsOthers
Price$45.99$124.99$125.99$189$69.99-99.99
Up-to-Date Dumps
Free 365 Days Update
Real Questions
Printable PDF
Test Engine
One Time Purchase
Instant Download
Unlimited Install
100% Pass Guarantee
100% Money Back
Secure Payment
Privacy Protection

Leave a Reply

Your email address will not be published. Required fields are marked *