Do not worry about that if you are stuck in the HP2-T25 exam difficulties, CertBus will assist you all your way through the HP2-T25 exam with the most update HP2-T25 PDF and VCE dumps. CertBus exam HP2-T25 preparation materials are the most comprehensive material, covering every key knowledge of HP2-T25 exam.
We CertBus has our own expert team. They selected and published the latest HP2-T25 preparation materials from Official Exam-Center: http://www.certgod.com/
QUESTION NO: 5
What is the term that describes the full backup typically performed by a system administrator every week?
A. grandfather, father, son
B. fathers
C. grandmothers
D. sons
Correct Answer: A
Explanation
Explanation/Reference:
Explanation:
GRANDFATHER-FATHER-SON BACKUP STRATEGY
GFS (grandfather, father, son) is a tape rotation strategy. GFS simplifies tape handling by organizing
rotation into daily, weekly, and monthly backup tapes. You can also create Custom backup jobs that use
the GFS strategy.
QUESTION NO: 2
Which statement is correct about the HP iLO Management Engine?
A. The health driver (agent management) is the only tool for SIM to collect server information from the iLO
Management Engine.
B. Intelligent Provisioning is one of the major features residing in the iLO Management Engine.
C. The Active Health feature in the iLO Management Engine does not monitor hardware.
D. It does not apply to ProLiant 100 G8 series.
Correct Answer: B
Explanation
Explanation/Reference:
Explanation:
Features under HP iLO Management Engine include, HP iLO, HP Intelligent Provisioning, HP Agentless
Management and HP Active Health System.
QUESTION NO: 8
Which key must you press to access the Intelligence Provisioning Maintenance Menu?
A. F9
B. F10
C. F11
D. F12
Correct Answer: B
Explanation
Explanation/Reference:
Explanation:
Boot options
Near the end of the boot process, the boot options screen is displayed. This screen is visible for several
seconds before the system attempts to boot from a supported boot device. During this time, user can do
the following:
Access RBSU by pressing the F9 key.
Access Intelligent Provisioning Maintenance Menu by pressing the F10 key.
Access the boot menu by pressing the F11 key.
Force a PXE Network boot by pressing the F12 key.
QUESTION NO: 7
Which RAID level allows the data to be striped across multiple RAIDs? (Select two.)
A. RAID 0
B. RAID 1
C. RAID 5
D. RAID 50
E. RAID 60
Correct Answer: DE
Explanation
Explanation/Reference:
Explanation:
D: RAID level 50 is a combination of RAID level 5 and RAID level 0. RAID 50 includes both parity and disk
striping across multiple drives. RAID 50 is best implemented across two RAID 5 arrays with data striped
across both disk arrays. RAID 50 breaks the data into smaller blocks, and then stripes the blocks to each
RAID 5 raid set. RAID 5 breaks up data into smaller blocks, calculates parity by performing and Exclusive
OR on the blocks, and then writes the blocks of data and parity to each drive in the array. The size of each
block is determined by the stripe size parameter, which is set when the RAID is created.
E: A RAID 60 combines the straight block-level striping of RAID 0 with the distributed double parity of RAID
6. That is, a RAID 0 array striped across RAID 6 elements. It requires at least eight disks.
Incorrect:
Not A: It is striped, but not across multiple RAIDs.
Not B: Mirror not a stripe.
Not C: Just a single raid.
QUESTION NO: 6
Which tool should you use to configure an MSA2312FC?
A. Option ROM Configuration for Arrays
B. Array Configuration Utility
C. Array Diagnostic Utility
D. Storage Management Utility
E. Intelligent Provisioning
Correct Answer: B
Explanation
Explanation/Reference:
Explanation:
The HP Array Configuration Utility (ACU) provides online, high availability configuration, management, and
diagnostic capabilities in support of all Smart Array products and particular HP ProLiant Storage RAID
Array Controllers.
Hardware Requirements:
Smart Array Controllers (Windows and Linux support)
MSA 500, MSA 1000, MSA 1500 (Windows and Linux support) Storage Enclosure 4×00 family of products
(Windows support only)
QUESTION NO: 9
Which RAID level is known as Advance Data Guarding (ADG)?
A. RAID 1
B. RAID 5
C. RAID 6
D. RAID 10
Correct Answer: C
Explanation
Explanation/Reference:
Explanation:
RAID 6 with HPs patented Advanced Data Guarding (ADG) technology is a cost-effective solution for
storing large volumes of enterprise data with fault tolerance. Its performance, like that of other RAID levels,
depends on the nature of the application. Organizations implementing a large drive array should consider
RAID 6 because it can tolerate up to two simultaneous drive failures without downtime or data loss.
QUESTION NO: 4
Which hardware-based system security feature can securely store information, such as passwords and
encryption keys, and can be used to authenticate the platform?
A. TPM
B. DHCP
C. RBSU
D. ORCA
Correct Answer: A
Explanation
Explanation/Reference:
Explanation:
The TPM (Trusted Platform Module) is a hardware-based system security feature that can securely store
information, such as passwords and encryption keys, which can be used to authenticate the platform.
QUESTION NO: 10
What is achieved on ProLiant Gen8 Servers by including temperature sensors on stand-up components
within the server (3D Sea of Sensors)?
A. Cooling fans on stand-up components only run at 50% utilization.
B. It provides more precise and more efficient cooling.
C. It requires half the number of fans than in previous server models.
D. Dedicated cooling fans are included on all stand-up components.
Correct Answer: B
Explanation
Explanation/Reference:
Explanation:
HP Sea of Sensors 3D
Introduced with ProLiant G6 servers, HP Sea of Sensors provides the data to precisely control the server
fans and directly cool specific components, while not overcooling other components.
This can reduce fan power consumption up to dozens of watts per server. HP Sea of Sensors 3D in
ProLiant Gen8 servers extends the use of sensors to select PCI Express option cards,
FlexibleNetwork Adapters, and FlexFabric Adapters to get a three-dimensional temperature profile in the
server. This additional data enables more precise and efficient cooling of ProLiant
Gen8 servers. The data is included in the always-on diagnostic information of the HP Active Health
System.
QUESTION NO: 3
Which LED is a new feature for the 6 GB SATA disk drive in Gen8 servers?
A. Configuration
B. Activity
C. Do Not Remove
D. Unit
Correct Answer: C
Explanation
Explanation/Reference:
Explanation:
What’s new
* Introducing all new 6Gb/sec SATA Midline drives with enhanced data rate, exclusively for use with all
new HP ProLiant Gen8 servers and available in a wide range of capacity points
* Entirely re-designed Small Form Factor (SFF) and Large Form Factor (LFF) universal hot plug carriers
exclusively for HP ProLiant Gen8 servers
* Intuitively designed drive activity and status LEDs and a DO NOT Remove indicator compatible with
Gen8 Smart Array controllers
QUESTION NO: 1
Which type of memory is used on the Smart Array controller cache?
A. SDRAM
B. SRAM
C. RDRAM
D. DRAM
Correct Answer: D
Explanation
Explanation/Reference:
Explanation:
Error checking and correcting (ECC) DRAM technology protects the data while it is in cache. Smart Array
battery-backed or flash-backed cache backup mechanisms protect the cache data
against a server crash and power loss.
HP2-T25 exam dumps (100% Pass Guaranteed) from CertBus: http://www.certgod.com/ [100% Exam Pass Guaranteed]
Why select/choose CertBus?
Millions of interested professionals can touch the destination of success in exams by certgod.com. products which would be available, affordable, updated and of really best quality to overcome the difficulties of any course outlines. Questions and Answers material is updated in highly outclass manner on regular basis and material is released periodically and is available in testing centers with whom we are maintaining our relationship to get latest material.