Free Download the Most Update CertBus Network Appliance NS0-120 Brain Dumps
Which certification is the most popular and worthy to get? No doubt the NS0-120 Data ONTAP Advanced Exam exam is a worth challenging task but you should take among all the IT certifications . CertBus is providing the latest version of NS0-120 PDF and VCE dumps now. Comprehensive understanding on NS0-120 Data ONTAP Advanced Exam exam syllabus through CertBus 100% pass guarantee of the success on your NS0-120 Data ONTAP Advanced Exam exam taking.
We CertBus has our own expert team. They selected and published the latest NS0-120 preparation materials from Network Appliance Official Exam-Center: http://www.certgod.com/NS0-120.html
QUESTION NO:105
A customer has bought an IBM System Storage DS8700 and wants to attach ten SuSE Linux Enterprise
Server hosts to the DS8700 with multiple paths. What is the Multipathing Driver the customer needs?
A. PowerPath
B. Subsystem Device Driver Device Specific Module
C. Subsystem Device Driver Path Control Module
D. DeviceMapper Multipath
Correct Answer: D
QUESTION NO:146
IBM support asks that currently active system firmware level (MHxxxxx) be deactivated, so the system can run on the older level. How is this accomplished?
A. Run command DLTPTF PTE (M) RMV (*TEMP).
B. Run the WRKFMWSTS command. Select option 4 on the *TEMP line and press “enter”.
C. On the system panel, change the IPL mode to “B” and “P. Then restart the system.
D. Run command RMVPTF LICPGM(5770SS1)SELECT(MHxxxxx) DELAYED(*YES),then restart the partition.
Correct Answer: C
QUESTION NO:6
A customer requires an infrastructure to support disaster recovery of critical applications between two
remote data centers. One data center is in Tokyo and one is in Beijing. The customer’s Recovery Point
Objective (RPO) requires a six-hour window for a bandwidth of 100 MB/s and a new storage system for a
total of 4 TB of data. They estimate 100 MB of new data produced hourly. What data synchronization
method would be recommended to meet the requirements?
A. Metro Mirror
B. FlashCopy
C. Global Mirror
D. Snapshot
Correct Answer: C
QUESTION NO:110
A rendering system that gets XML information from back-end data sources has to display binary
image files. Also, the rendering system should handle multiple rendering targets like web
browsers, hand-held phones, and PDAs. What is the BEST way to send the binary image
information to the rendering system?
A. The rendering system should have a component to convert binary images from one format to
another.
B. XLink should be used to identity the image location for each device that can be used by the
device to display the image.
C. XSL FO can be used to format binary image objects for different rendering targets.
D. Images should be embedded as attachments to the XML documents sent to rendering
system.
Answer: B
Page 34 of 34
QUESTION NO: 176
An architect is considering whether to specify vSCSI or NPIV for the rootvg disks in a new virtualized
environment. Storage is to be provided by an IBM San Volume Controller (SVC) and controlled using
SDDPCM.
Which of the following is an advantage of using vSCSI technology instead of NPIV?
A. Support for vSCSI devices is included within base AIX, removing the need to install device drivers at
the client level.
B. Queue depths higher than 20 for rootvg disks are supported with vSCSI.
C. vSCSI allows for client level logical volume mirroring for rootvg, providing enhanced protection.
D. vSCSI provides active/active multi pathing, allowing I/O requests to be distributed between dual VIOS
partitions
Correct Answer: A